Crystal Quest C-100 RO system control panel with digital display, status LEDs, and power/setpoint buttons.

Crystal Quest C-100 Reverse Osmosis System Control Panel

$2,589.00
Sale price  $2,589.00 Regular price 
Skip to product information
Crystal Quest C-100 RO system control panel with digital display, status LEDs, and power/setpoint buttons.

Crystal Quest C-100 Reverse Osmosis System Control Panel

$2,589.00
Sale price  $2,589.00 Regular price 

Overview

Crystal Quest C-100 Controller available from Healthy Hydro Supply Co is a reverse osmosis system controller designed for monitoring and control of light commercial reverse osmosis units.

This controller supports RO system automation, water quality monitoring, pump control, valve control, membrane flush control, pressure switch monitoring, tank level monitoring, and system protection.

Product Information

  • Product Name: Crystal Quest C-100 Controller
  • Brand: Crystal Quest
  • Sold By: Healthy Hydro Supply Co
  • Product Type: Reverse osmosis system controller
  • Primary Use: Monitoring and control of light commercial reverse osmosis units
  • Application: Light commercial RO system automation, water quality monitoring, pump control, valve control, and system protection
  • TDS Range: 0–1000 PPM
  • Display: Three-digit LED display
  • Mounting: Panel-mountable enclosure
  • Power: 120 VAC or 240 VAC, 15+10%, 50/60Hz
  • Enclosure: 8.25" x 5.0" x 3.0" ABS plastic

Description

The Crystal Quest C-100 Controller is an economical monitoring and control solution designed for light commercial reverse osmosis systems.

It helps manage key RO system functions, including pump operation, inlet valve control, membrane flushing, pressure switch monitoring, storage tank level monitoring, pretreatment lockout, and water quality status.

The controller provides relays for the RO pump, inlet solenoid valve, and membrane flush solenoid valve. Dry contact switch inputs monitor the storage tank level, low-pressure switch signal, high-pressure switch signal, and system lockout for pretreatment backwash or regeneration during on/off operation.

All inputs and outputs are controlled with time delays to support proper system operation. This helps coordinate pump, valve, flush, pressure, and tank-level signals for compatible RO system applications.

The C-100 Controller also includes a TDS monitor with sensor rated for a 0–1000 PPM range. The TDS value includes a field-adjustable set point for setting the water quality threshold. If the threshold is exceeded, the controller can produce a system warning to help users monitor RO membrane performance and overall water quality.


Benefits

The Crystal Quest C-100 Controller is designed for customers who need monitoring, automation, and control support for compatible light commercial reverse osmosis systems.

Key Benefits

  • Provides an economical RO control solution
  • Supports light commercial reverse osmosis system automation
  • Controls RO pump relay operation
  • Controls inlet solenoid valve relay operation
  • Controls membrane flush solenoid valve relay operation
  • Monitors RO storage tank level
  • Monitors low-pressure switch signal
  • Monitors high-pressure switch signal
  • Supports system lockout for pretreatment backwash or regeneration
  • Supports on/off operation control
  • Uses time delay control for proper input and output operation
  • Includes TDS monitor with sensor
  • TDS monitoring range is 0–1000 PPM
  • Includes field-adjustable TDS set point
  • Provides water quality threshold warning when set point is exceeded
  • Uses LED indicators for water quality and operating status
  • Includes three-digit LED display
  • Includes jumper-selectable flush type
  • Includes jumper-selectable switch inputs
  • Includes TDS calibration adjustment
  • Includes TDS setpoint adjustment
  • Includes quick-disconnect high-voltage terminals
  • Includes plug-in terminals for switch inputs
  • Uses a panel-mountable enclosure

Best For

  • Light commercial reverse osmosis systems
  • RO system automation
  • RO pump control
  • RO inlet valve control
  • RO membrane flush control
  • RO storage tank level monitoring
  • RO pressure switch monitoring
  • Pretreatment lockout applications
  • Reverse osmosis TDS monitoring
  • Water quality threshold monitoring
  • RO membrane performance monitoring
  • Compatible RO systems needing visual LED status feedback
  • Compatible RO systems needing time delay input/output control

Performance

The Crystal Quest C-100 Controller helps manage key reverse osmosis system control functions for compatible light commercial RO units.

Control Functions

  • RO pump relay control
  • Inlet solenoid valve relay control
  • Membrane flush solenoid valve relay control
  • Storage tank level monitoring
  • Low-pressure switch signal monitoring
  • High-pressure switch signal monitoring
  • System lockout for pretreatment backwash or regeneration
  • On/off operation control
  • Time delay control for proper input and output operation

Water Quality Monitoring

  • TDS monitor with sensor
  • TDS range of 0–1000 PPM
  • Field-adjustable TDS set point
  • Water quality threshold warning when set point is exceeded
  • LED indicators for water quality and operating status
  • Supports RO membrane performance monitoring
  • Supports overall RO water quality monitoring

Controller Features

  • Economical control solution
  • Visual status LED
  • TDS monitor with sensor
  • Three-digit LED display
  • Jumper-selectable flush type
  • Jumper-selectable switch inputs
  • TDS calibration adjustment
  • TDS setpoint adjustment
  • Quick-disconnect high-voltage terminals
  • Plug-in terminals for switch inputs
  • Panel-mountable enclosure

Contaminants / Water Quality Concerns Addressed

  • This product does not directly filter water.
  • This product does not directly remove contaminants.
  • This product supports RO system monitoring and control.
  • This product monitors TDS within a 0–1000 PPM range.
  • This product helps warn when the field-adjustable TDS threshold is exceeded.
  • This product helps users monitor RO membrane performance and overall water quality in compatible systems.

Performance Notes

  • The C-100 Controller is a control and monitoring component, not a complete reverse osmosis system.
  • RO water treatment performance depends on the connected reverse osmosis system, membrane condition, feed water quality, prefiltration, pressure, installation, and maintenance.
  • Do not claim the controller removes TDS or contaminants by itself.
  • The controller monitors TDS and helps manage system operation in compatible RO applications.

Specs

Product Specifications

Specification Value
Product Name Crystal Quest C-100 Controller
Brand Crystal Quest
Sold By Healthy Hydro Supply Co
Product Type Reverse osmosis system controller
Primary Use Monitoring and control of light commercial reverse osmosis units
Application Light commercial RO system automation, water quality monitoring, pump control, valve control, and system protection
Power 120 VAC or 240 VAC, 15+10%, 50/60Hz
Environment -22°F to 140°F, 0–95% RH, non-condensing
Enclosure 8.25" x 5.0" x 3.0" ABS plastic
TDS Range 0–1000 PPM
Display Three-digit LED display
Mounting Panel-mountable enclosure

Input / Output Switches

Input / Output Switch Detail
Low-pressure switch Supported
RO storage tank full Supported
Pretreatment lockout Supported
Switch Input Type All switch inputs are jumper-selectable NO or NC

Control Relays

Control Relay Rating
Inlet solenoid valve 120/240 VAC, 5 amp maximum
RO pump 120/240 VAC, 1 HP, single phase maximum
Flush solenoid valve 120/240 VAC, 5 amp maximum

Primary Control Focus

  • Reverse osmosis system controller
  • Light commercial RO automation
  • RO pump relay control
  • Inlet solenoid valve control
  • Membrane flush solenoid valve control
  • RO storage tank level monitoring
  • Low-pressure switch monitoring
  • High-pressure switch monitoring
  • Pretreatment lockout
  • Time delay operation
  • TDS monitoring
  • Water quality threshold warning
  • RO membrane performance monitoring

Install & Parts

The Crystal Quest C-100 Controller should be selected for compatible light commercial reverse osmosis systems that require pump control, valve control, pressure switch monitoring, storage tank level monitoring, pretreatment lockout, and TDS monitoring.

System Design Should Be Based On

  • Reverse osmosis system compatibility
  • Light commercial RO application
  • Pump control requirements
  • Inlet solenoid valve control requirements
  • Membrane flush solenoid valve control requirements
  • Low-pressure switch requirements
  • High-pressure switch requirements
  • RO storage tank full signal
  • Pretreatment backwash or regeneration lockout needs
  • TDS monitoring needs
  • Desired TDS set point
  • Water quality warning requirements
  • Time delay control requirements
  • Power requirement: 120 VAC or 240 VAC
  • Environment range: -22°F to 140°F, 0–95% RH, non-condensing
  • Panel mounting location
  • High-voltage terminal access
  • Switch input terminal access

Installation Instructions

Parts & Accessories

  • Specific replacement parts and accessories were not provided in the source product content.
  • Source content lists input/output switches and control relays as part of the controller details.

Installation / Use Notes

  • The controller includes quick-disconnect high-voltage terminals.
  • The controller includes plug-in terminals for switch inputs.
  • The controller uses a panel-mountable enclosure.
  • All inputs and outputs are controlled with time delays to support proper system operation.
  • Dry contact switch inputs monitor storage tank level, pressure switch signals, and system lockout conditions.

Important Notes

  • No warranty terms were provided in the source product content.
  • No complete compatible RO model list was provided in the source product content.
  • No installation step-by-step details were provided in the source product content.
  • This product is a controller, not a complete reverse osmosis system.
  • This product monitors TDS but does not remove TDS by itself.
  • RO water treatment performance depends on the connected RO system, membrane condition, feed water quality, pressure, installation, and maintenance.

FAQ & Support

What is the Crystal Quest C-100 Controller?

The Crystal Quest C-100 Controller is a reverse osmosis system controller designed for monitoring and control of light commercial reverse osmosis units.

What is this controller used for?

It is used for light commercial RO system automation, water quality monitoring, pump control, valve control, membrane flush control, pressure switch monitoring, storage tank monitoring, and system protection.

Does the C-100 Controller include TDS monitoring?

Yes. It includes a TDS monitor with sensor and a 0–1000 PPM range.

Can the TDS set point be adjusted?

Yes. The controller includes field-adjustable TDS set point adjustment.

What happens when the TDS threshold is exceeded?

The controller can provide a water quality threshold warning when the set point is exceeded.

What display does the controller use?

The controller includes a three-digit LED display.

Does the controller have status indicators?

Yes. It includes LED indicators for water quality and operating status.

What does the controller control?

It controls the RO pump relay, inlet solenoid valve relay, and membrane flush solenoid valve relay.

What switch inputs does it monitor?

It monitors storage tank level, low-pressure switch signal, high-pressure switch signal, and system lockout for pretreatment backwash or regeneration.

Does the controller support time delay operation?

Yes. All inputs and outputs are controlled with time delays to support proper system operation.

What is pretreatment lockout?

Pretreatment lockout allows the controller to respond to pretreatment backwash or regeneration conditions so the RO system can be protected during operation.

What power does the controller use?

The controller uses 120 VAC or 240 VAC, 15+10%, 50/60Hz.

What is the operating environment range?

The environment range is -22°F to 140°F and 0–95% RH, non-condensing.

What is the enclosure size?

The enclosure is 8.25" x 5.0" x 3.0" ABS plastic.

What are the control relay ratings?

The inlet solenoid valve is rated 120/240 VAC, 5 amp maximum. The RO pump is rated 120/240 VAC, 1 HP, single phase maximum. The flush solenoid valve is rated 120/240 VAC, 5 amp maximum.

Is this a complete reverse osmosis system?

No. This is a controller for compatible light commercial reverse osmosis systems, not a complete RO system.

Does this controller remove TDS or contaminants?

No. The controller monitors TDS and controls RO system functions, but it does not filter water or remove contaminants by itself.