Low-Flow Reverse Osmosis System
Overview
Product Information
- Product name: Crystal Quest Low-Flow Reverse Osmosis System
- Brand: Crystal Quest
- Sold by: Healthy Hydro Supply Co
- Product type: Low-flow commercial reverse osmosis system
- Installation type: Point-of-entry or application-specific RO system
- Production options: 200 or 300 gallons per day
- Published production temperature: 77°F
- Primary membrane type: Thin-film composite high-flow membrane
- Membrane quantity: One
- Prefiltration: Sediment, SMART, and carbon-block cartridges
- Optional features: Automatic membrane flushing and concentrate recirculation
- Manufacturing: Made in the USA
Description
The Crystal Quest Low-Flow Reverse Osmosis System is designed for commercial and point-of-entry applications that require approximately 200 or 300 gallons of reverse-osmosis-treated water per day.
Water passes through sediment, SMART, and carbon-block prefiltration before reaching a thin-film composite reverse osmosis membrane. This combination helps protect the membrane from suspended material and supports the reduction of dissolved salts and total dissolved solids.
The 200 GPD and 300 GPD systems use different membrane sizes, equipment dimensions, operating pressures, and production capacities. Optional automatic flushing and concentrate-recirculation features are available for applications that need additional membrane-maintenance or water-recovery support.
Important Notes
- The 200 and 300 GPD ratings are based on water at 77°F under specified operating conditions.
- Lower water temperature, higher dissolved-solids levels, and changes in incoming pressure can reduce daily production.
- Gallons per day measures production capacity. It does not represent the instantaneous delivery rate available at a faucet or fixture.
- A compatible storage and delivery system may be required when demand occurs faster than the RO system can produce water.
- Reverse osmosis produces treated water and a separate concentrate stream that must discharge to an unrestricted drain.
- Feed water must be tested and properly pretreated before entering the RO membrane.
- Chlorine must be addressed before the membrane.
- Hard water, iron, manganese, sediment, silica, organics, and high TDS can cause membrane scaling or fouling if pretreatment is inadequate.
- Reverse osmosis is not a substitute for microbiological disinfection.
- Published dimensions and several operating specifications conflict between the product listing and operating manual. Confirm the final system footprint and installation requirements before ordering.
- No model-specific certification or certified contaminant-reduction report was identified for the complete system.
Benefits
Key Benefits
- Two production capacities: Choose between 200 and 300 gallons per day based on the application’s expected daily water demand.
- Multi-stage prefiltration: Sediment, SMART, and carbon-block cartridges help prepare the incoming water before it reaches the membrane.
- Thin-film composite membrane: Uses one high-flow, low-energy TFC reverse osmosis membrane.
- Dissolved-solids reduction: Published sodium-chloride rejection ranges from 96% minimum to 98.5% maximum under the stated operating conditions.
- Compact commercial design: Built for lower-volume commercial and point-of-entry RO applications.
- Optional automatic flushing: An available auto-flush feature helps move accumulated material across the membrane surface.
- Optional concentrate recirculation: Allows part of the concentrate stream to return to the system feed when application conditions permit.
- Storage-control capability: The system can be configured to operate with a storage-tank liquid-level switch.
- Serviceable filtration components: Prefilter cartridges and RO membranes can be replaced individually.
- Made in the USA: Manufacturer documentation identifies the equipment as made in the United States.
Best For
- Small commercial operations with moderate daily RO-water requirements
- Facilities requiring approximately 200 or 300 gallons of treated water per day
- Application-specific water-treatment installations
- Point-of-entry projects with compatible storage and delivery equipment
- Businesses that have tested their water and established the necessary pretreatment
- Properties with sufficient feed pressure, electrical service, drainage, and installation space
- Applications requiring reduction of dissolved salts and total dissolved solids
- Buyers who need a serviceable commercial RO system with replaceable prefilters and membrane elements
Performance
Reverse Osmosis Performance
Feed water first passes through three prefiltration stages before entering the thin-film composite membrane. Pressure moves part of the water through the membrane as treated permeate, while the remaining concentrate carries rejected dissolved material to the drain.
- Available production capacities: 200 or 300 gallons per day
- Published production temperature: 77°F
- Published minimum sodium-chloride rejection: 96%
- Published maximum sodium-chloride rejection: 98.5%
- Manual-listed recovery range: Approximately 33%–50%
- Higher projected recovery: Up to 75% when supported by a system projection and compatible water conditions
- Maximum published feed rate: 3 GPM
- Minimum published feed rate: 1 GPM
- Operating pH range: 3–11
- Maximum published hardness: 15 grains per gallon
Actual production and rejection depend on feed-water temperature, pressure, TDS, chemistry, pretreatment, membrane condition, and system adjustment.
Prefiltration Stages
- Pleated sediment cartridge
- SMART filter cartridge
- Coconut-based 5-micron carbon-block cartridge
- Thin-film composite reverse osmosis membrane
Contaminants Addressed
The filtration process is designed to address:
- Sediment and suspended particles through prefiltration
- Total dissolved solids through reverse osmosis
- Dissolved salts, including manufacturer-tested sodium chloride
- Feed-water concerns addressed by the selected sediment, SMART, and carbon-block prefilters
No certified percentage was provided for individual contaminants such as arsenic, fluoride, nitrate, lead, PFAS, pesticides, pharmaceuticals, bacteria, or viruses. Do not interpret the published sodium-chloride rejection percentage as a certified reduction percentage for every dissolved contaminant.
Specs
200 GPD System
- Rated production: 200 gallons per day at 77°F
- Published system dimensions: 7 × 22 × 31 inches
- Approximate weight: 50 pounds
- Membrane size: 2514 TFC HF1
- Number of membranes: One
- Concentrate recirculation: Optional
- Automatic flushing: Optional
- Motor horsepower: Not listed
- Published voltage: 110/220V AC
- Published frequency: 50/60 Hz
- Feed connection: ⅜ inch
- Product-water connection: ⅜ inch
- Waste connection: ¼ inch
- Minimum feed pressure: 45 psi
- Operating pressure: 50 psi
- Minimum feed rate: 1 GPM
- Maximum feed rate: 3 GPM
- Maximum hardness: 15 grains per gallon
- Maximum TDS: 1,000 ppm
- Operating pH range: 3–11
- Minimum sodium-chloride rejection: 96%
- Maximum sodium-chloride rejection: 98.5%
300 GPD System
- Rated production: 300 gallons per day at 77°F
- Published system dimensions: 7 × 28 × 33 inches
- Approximate weight: 70 pounds
- Membrane size: 2521 TFC HF1
- Number of membranes: One
- Concentrate recirculation: Optional
- Automatic flushing: Optional
- Motor horsepower: Not listed
- Published voltage: 110/220V AC
- Published frequency: 50/60 Hz
- Feed connection: ⅜ inch
- Product-water connection: ⅜ inch
- Waste connection: ¼ inch
- Minimum feed pressure: 45 psi
- Operating pressure: 150 psi
- Minimum feed rate: 1 GPM
- Maximum feed rate: 3 GPM
- Maximum hardness: 15 grains per gallon
- Maximum TDS: 1,000 ppm
- Operating pH range: 3–11
- Minimum sodium-chloride rejection: 96%
- Maximum sodium-chloride rejection: 98.5%
General Feed-Water Conditions
- Feed water must be filtered and dechlorinated.
- Published feed-water temperature range is 40°F–105°F.
- Lower temperatures and higher TDS can reduce membrane production.
- Pretreatment may be necessary for hardness, iron, manganese, silica, organics, turbidity, or scaling conditions.
- Final equipment dimensions, electrical requirements, connections, and operating pressure should be confirmed before installation.
Install & Parts
Installation Requirements
- Install the system securely on a level surface.
- Secure or bolt down the freestanding frame in accordance with applicable regulations.
- Confirm the electrical supply matches the selected system.
- Electrical service must include a protective earth ground.
- Electrical work should be completed by a licensed electrician in accordance with local and national codes.
- Provide a continuous supply of filtered, properly pretreated water.
- Install adequate chlorine-removal treatment before the RO membrane.
- Connect the concentrate line to an unrestricted drain without back pressure.
- Use product-water plumbing materials compatible with RO permeate.
- Avoid untreated copper plumbing where lower-pH RO permeate could cause corrosion.
- Confirm that the product-water line can flow freely without back pressure.
- Test the feed water before selecting pretreatment and operating settings.
- A compatible storage tank, level switch, and delivery pump may be required for the intended application.
- Flush new membranes and direct the initial permeate and concentrate to drain before placing the system into service.
- Maintain an operating log as required by the manufacturer’s warranty instructions.
Replacement Components Used by Both Systems
Pleated Cellulose Sediment Cartridge
- Size: 2⅞ × 20 inches
SMART Filter Cartridge
- Size: 2⅞ × 20 inches
Coconut-Based 5-Micron Carbon-Block Cartridge
- Size: 2⅞ × 20 inches
200 GPD Replacement Membrane
- Size: 2½ × 14 inches
- Membrane type: Freshwater thin-film composite RO membrane
300 GPD Replacement Membrane
- Size: 2½ × 21 inches
- Membrane type: Freshwater thin-film composite RO membrane
Maintenance
- Monitor the pressure before and after the prefilters.
- A pressure difference of approximately 10–15 psi indicates that prefilter service may be required.
- Do not attempt to clean and reuse disposable filter cartridges.
- Flush the membrane system weekly for approximately 10–20 minutes when automatic flushing is not installed.
- Inspect the system regularly for leaks, restricted flow, unusual pressure, and changes in permeate production.
- Properly pretreated membranes may provide approximately two to three years of service before salt rejection changes significantly.
- Membrane life can be shortened by chlorine exposure, excessive hardness, scaling, fouling, improper pressure, high TDS, or inadequate maintenance.
- Divert permeate to drain after membrane cleaning until the water is clear and cleaning residue has been removed.
FAQ & Support
What is the difference between the 200 GPD and 300 GPD systems?
The primary differences are daily production capacity, membrane size, equipment dimensions, weight, and published operating pressure. Select the system according to tested water conditions, required daily production, storage capacity, and installation requirements.
Does 300 GPD mean the system can supply five gallons per minute?
No. GPD represents the amount the system is designed to produce over 24 hours under specified conditions. A 300 GPD rating equals an average production rate of approximately 0.21 gallons per minute before accounting for temperature and other operating conditions.
Will the system deliver water directly to every fixture?
That depends on the application. RO production is gradual, so many installations use a storage tank and delivery pump to meet short periods of higher demand.
Does the system require pretreatment?
Yes. The system must receive filtered and dechlorinated feed water. Additional pretreatment may be required for hardness, iron, manganese, sediment, silica, organics, or other scaling and fouling conditions.
Does reverse osmosis produce wastewater?
Yes. The system separates water into treated permeate and a concentrate stream. The concentrate line must discharge freely to an approved drain without back pressure.
Does this system remove every contaminant?
No. Published sodium-chloride rejection does not establish a certified reduction percentage for every contaminant. Treatment suitability should be based on water-test results and documented product performance.
Can the system treat microbiologically unsafe water?
Reverse osmosis should not be treated as a substitute for microbiological disinfection. Source water with bacteria, viruses, or other microbial concerns requires appropriate testing and treatment.
Why can actual production be lower than the stated GPD rating?
Colder water, higher TDS, insufficient pressure, membrane fouling, inadequate pretreatment, and worn components can reduce production.
What warranty is listed?
The current operating manual lists a 12-month limited manufacturer warranty against defects in materials and workmanship when the equipment is installed, operated, and maintained within the specified conditions.
Disposable filters, cartridges, fuses, and similar maintenance items are excluded. Warranty eligibility also depends on documentation, installation timing, operating records, and adherence to feed-water requirements.
Where can I get help confirming system requirements?
Contact a Healthy Hydro Supply Co associate for assistance with capacity, feed-water testing, pretreatment, storage, installation planning, or replacement components.