Medical Mid-Flow Reverse Osmosis System (500-7000 GPD)
Overview
Product Information
- Product name: Crystal Quest Medical Mid-Flow Reverse Osmosis System
- Product type: Commercial reverse osmosis water treatment system
- Brand: Crystal Quest
- Rated production options: 500, 750, 1,000, 1,500, 1,800, 2,500, 4,000, 5,000, and 7,000 gallons per day
- Membrane type: Thin-film composite high-flow reverse osmosis membranes
- Frame construction: White powder-coated aluminum
- Membrane housing material: Stainless steel
- Installation format: Freestanding, pre-plumbed, wired, and assembled
- Country of manufacture: Made in the USA
- Available configurations:
- Standalone system
- 20-gallon bladder tank
- 28-gallon bladder tank
- 30-gallon bladder tank
- 40-gallon bladder tank
- 165-gallon atmospheric storage tank kit
- Available pump selections:
- Brass rotary pump
- Stainless steel rotary pump
- 1.5 HP horizontal pump
- Optional equipment varies by system size and selected configuration.
Description
The Crystal Quest Medical Mid-Flow Reverse Osmosis System is a configurable commercial water treatment platform with production capacities from 500 to 7,000 gallons per day.
The system combines thin-film composite reverse osmosis membranes, stainless steel membrane housings, pressure monitoring, permeate and concentrate flow meters, automatic feed-water control, and pump-protection components on a corrosion-resistant aluminum frame.
Multiple production capacities, storage configurations, pump selections, controls, and monitoring upgrades allow the system to be configured around available feed water, daily treated-water demand, peak usage, and installation requirements.
Best For
- Commercial facilities requiring 500 to 7,000 gallons of treated water per day under published operating conditions
- Properties requiring centralized reverse osmosis water production
- Applications that need atmospheric or pressurized water storage
- Facilities requiring configurable pumps, controls, monitoring, and storage
- Projects with documented feed-water chemistry and predictable daily demand
- Institutional or technical applications where the final treated-water specification will be independently validated
Important Notes
- Gallons-per-day ratings represent total production over 24 hours, not instantaneous delivery at a fixture.
- Published production is based on controlled operating conditions. Colder water, higher feed-water TDS, low pressure, scaling, and membrane fouling can reduce output.
- Storage capacity and delivery-pump performance must be considered separately from the RO system’s daily production rating.
- Peak demand may require a storage tank and repressurization pump even when the daily GPD rating appears sufficient.
- A feed-water analysis is required to determine pretreatment needs and help protect the membranes from sediment, chlorine, hardness, iron, manganese, silica, and fouling.
- The system requires an unrestricted concentrate drain.
- Electrical requirements, pump selection, connection sizes, storage controls, and final equipment dimensions must be confirmed for the selected configuration before ordering.
- Medical, laboratory, pharmaceutical, or other regulated applications require independent confirmation that the final water quality and complete treatment design meet the facility’s applicable requirements.
- The manufacturer’s manuals require operating records to be maintained for warranty support.
- The manufacturer’s limited warranty covers qualifying defects for 12 months under its written conditions. Filters, cartridges, and other consumable components are excluded.
- Consult a Healthy Hydro Supply Co associate before ordering if the project has regulated water-quality requirements, unusual feed-water chemistry, or high peak demand.
Key Benefits
- Nine production capacities from 500 to 7,000 gallons per day
- Configurable for different daily demand and storage requirements
- Thin-film composite high-flow reverse osmosis membranes
- Stainless steel membrane housings
- Corrosion-resistant white powder-coated aluminum frame
- Compact, freestanding system design
- Pre-plumbed, wired, assembled, and factory tested
- Accessible components support routine inspection and service
- Permeate and concentrate flow meters provide visible operating information
- Prefilter and pump pressure gauges support system monitoring
- Low-pressure protection helps prevent pump operation without sufficient feed water
- Feed solenoid valve automatically controls incoming water
- High-pressure tank switch supports compatible pressurized-storage configurations
- Locking safety clips help secure push-and-pull fittings
- Optional digital TDS and conductivity monitoring
- Optional concentrate recirculation and automatic membrane flushing
- Optional storage, pump, controller, blending, sampling, and chemical-feed connections
- Made in the USA
Performance
Published Performance Conditions
- Production range: 500 to 7,000 gallons per day
- Published production temperature: 77°F
- Published test-water TDS: 550 ppm
- Published operating pressure: 150 psi
- Published test-water pH: 7
- Published test recovery: 50%
- Standard operating recovery: Approximately 33% to 50%
- Recovery may reach 75% when supported by a system projection and appropriate feed-water conditions
- Published minimum sodium chloride rejection: 96%
- Published nominal or maximum sodium chloride rejection: Up to 98.5%
- Maximum feed-water TDS: 2,000 ppm
- Maximum feed-water hardness: 15 grains per gallon
- Feed-water pH range: 3–11
- Published feed-water temperature range: 40–105°F
Actual production and rejection depend on feed-water temperature, pressure, chemistry, membrane condition, recovery setting, and pretreatment.
Contaminants Addressed
The reverse osmosis membrane stage is designed to reduce:
- Total dissolved solids
- Dissolved salts
- Sodium chloride under the published test conditions
- Dissolved mineral content that contributes to elevated TDS
Supporting prefiltration and properly selected pretreatment may help manage:
- Sediment
- Suspended particles
- Chlorine before the RO membranes
- Hardness that could cause membrane scaling
- Iron and manganese that could contribute to fouling
- Organic matter and turbidity that could affect membrane performance
Feed-Water Requirements
- Feed water must be filtered before entering the high-pressure pump and membranes.
- Chlorine removal is required before the reverse osmosis membranes.
- The pump must not be operated dry.
- Feed-water chemistry must remain within the limits specified for the selected system.
- Concentrate must discharge through an unrestricted drain line without backpressure.
- Recovery must be adjusted to the feed-water chemistry and approved system projection.
- Pretreatment requirements may include sediment filtration, carbon filtration, water softening, antiscalant dosing, or other treatment based on testing.
Specifications
500 GPD System
- Rated production: 500 gallons per day at 77°F
- Approximate frame dimensions: 14 x 20 x 27 inches
- Approximate weight: 140 pounds
- Membranes: Two 2521 TFC HF1 elements
- Motor: 1/2 HP
- Feed connection: 3/4 inch
- Product connection: 3/8 inch
- Waste connection: 3/8 inch
- Published feed-water range: 1.5–3 GPM
750 GPD System
- Rated production: 750 gallons per day at 77°F
- Approximate frame dimensions: 14 x 20 x 27 inches
- Approximate weight: 140 pounds
- Membranes: One 2540 TFC HF1 element
- Motor: 1/2 HP
- Feed connection: 3/4 inch
- Product connection: 3/8 inch
- Waste connection: 3/8 inch
- Published feed-water range: 1.5–3 GPM
1,000 GPD System
- Rated production: 1,000 gallons per day at 77°F
- Approximate frame dimensions: 14 x 20 x 27 inches
- Approximate weight: 145 pounds
- Membranes: Three 2521 TFC HF1 elements
- Feed connection: 1 inch
- Product connection: 3/8 inch
- Waste connection: 3/8 inch
- Published feed-water range: 1.5–3 GPM
- Confirm motor size before ordering.
1,500 GPD System
- Rated production: 1,500 gallons per day at 77°F
- Approximate frame dimensions: 14 x 20 x 46 inches
- Approximate weight: 160 pounds
- Membranes: Two 2540 TFC HF1 elements
- Motor: 3/4 HP
- Feed connection: 1 inch
- Product connection: 3/8 inch
- Waste connection: 3/8 inch
- Published feed-water range: 1.5–5 GPM
1,800 GPD System
- Rated production: 1,800 gallons per day at 77°F
- Approximate frame dimensions: 14 x 20 x 46 inches
- Approximate weight: 160 pounds
- Membrane: One 4040 TFC HF1 element
- Motor: 3/4 HP
- Feed connection: 1 inch
- Product connection: 3/8 inch
- Waste connection: 3/8 inch
- Published feed-water range: 1.5–5 GPM
2,500 GPD System
- Rated production: 2,500 gallons per day at 77°F
- Approximate frame dimensions: 19 x 23 x 46 inches
- Approximate weight: 180 pounds
- Membranes: Three 2540 TFC HF1 elements
- Motor: 3/4 HP
- Feed connection: 1 inch
- Product connection: 3/8 inch
- Waste connection: 3/8 inch
- Published feed-water range: 4–10 GPM
4,000 GPD System
- Rated production: 4,000 gallons per day at 77°F
- Approximate weight: 235 pounds
- Membranes: Two 4040 TFC HF1 elements
- Feed connection: 1 inch
- Product connection: 1 inch
- Waste connection: 1 inch
- Published feed-water range: 6–15 GPM
- Confirm frame dimensions and motor size before ordering.
5,000 GPD System
- Rated production: 5,000 gallons per day at 77°F
- Approximate frame dimensions: 30 x 38 x 47 inches
- Approximate weight: 250 pounds
- Membranes: Three 4040 TFC HF1 elements
- Motor: 1.5 HP
- Feed connection: 1 inch
- Product connection: 1 inch
- Waste connection: 1 inch
- Published feed-water range: 7–15 GPM
7,000 GPD System
- Rated production: 7,000 gallons per day at 77°F
- Approximate frame dimensions: 30 x 38 x 47 inches
- Approximate weight: 265 pounds
- Membranes: Four 4040 TFC HF1 elements
- Motor: 1.5 HP
- Product connection: 1 inch
- Waste connection: 1 inch
- Published feed-water range: 10–15 GPM
- Confirm the feed connection before ordering.
Common Operating Specifications
- Operating pressure: 150 psi
- Published sodium chloride rejection: 96% minimum and up to 98.5%
- Standard recovery range: Approximately 33% to 50%
- Maximum feed-water TDS: 2,000 ppm
- Maximum feed-water hardness: 15 grains per gallon
- Feed-water pH range: 3–11
- Feed-water temperature range: 40–105°F
- Electrical supply: Model-specific single-phase 110/220 or 120/220 VAC
- Frequency: Model-specific 50 or 60 Hz
- Concentrate recirculation: Optional
- Automatic membrane flushing: Optional
Install & Parts
Installation Requirements
- Install the system indoors on a level, stable surface.
- Secure the frame according to applicable building and installation requirements.
- Protect the equipment from freezing, excessive heat, weather, and inadequate ventilation.
- Provide sufficient clearance for cartridge, membrane, pump, and control-panel service.
- Confirm that the available electrical supply matches the selected motor and controller.
- Electrical work should be completed by a qualified electrician in accordance with applicable codes.
- Provide a properly grounded electrical connection.
- Provide filtered, dechlorinated feed water within the specified pressure, temperature, hardness, TDS, and pH limits.
- Install the concentrate line to an unrestricted drain.
- Do not create backpressure on the concentrate line.
- Do not operate the high-pressure pump without sufficient feed water.
- Use compatible product-water piping materials.
- Install the appropriate tank-level switch or pressure control for the selected storage configuration.
- Flush new or cleaned membranes according to the installation manual before directing product water to storage or use.
- Inspect all plumbing and electrical connections before startup.
- Record operating pressure, flow, conductivity or TDS, recovery, and feed-water conditions after startup.
Standard System Components
- White powder-coated aluminum frame
- Stainless steel membrane housing or housings
- Thin-film composite reverse osmosis membrane or membranes
- High-pressure pump and motor
- Stainless steel concentrate control valve
- Permeate flow meter
- Concentrate flow meter
- Prefilter pressure gauge
- Pump pressure gauge
- Low-pressure pump-protection switch
- High-pressure tank switch for compatible configurations
- Automatic feed-water solenoid valve
- Push-and-pull fittings with locking safety clips
- Prefilter housings
- Filter housing wrench
- Installation and operation documentation
- System test information
Available Storage Configurations
- Standalone system
- 20-gallon bladder tank
- 28-gallon bladder tank
- 30-gallon bladder tank
- 40-gallon bladder tank
- 165-gallon atmospheric storage tank kit
The 165-gallon atmospheric tank kit is listed with upper and lower float controls and a repressurization pump. Confirm the final tank-kit components and delivery-pump performance for the selected system.
Available Upgrades
- Stainless steel rotary pump
- Concentrate recirculation valve
- Automatic membrane flushing
- Digital dual TDS controller
- Digital TDS controller
- Digital TDS and conductivity controller
- S150 controller with feed flush
- Pretreatment lockout input
- Tank-level input
- Status display and alarm functions
- Chemical-feed pump electrical outlet
- Product-water blending valve
- Permeate sample port
- Alternative voltage and frequency configurations
- Protective wood crate
Replacement Component Categories
Depending on system capacity, replacement components may include:
- Pleated sediment filter cartridge
- SMART filter cartridge
- Granular activated carbon cartridge
- Five-micron carbon block cartridge
- 2521 reverse osmosis membrane
- 2540 reverse osmosis membrane
- 4040 reverse osmosis membrane
- Housing seals and O-rings
- Pump service components
- Flow, pressure, and control components
Replacement filters and membranes must be matched to the system’s exact production capacity, model, serial number, and installed configuration. Contact a Healthy Hydro Supply Co associate before ordering replacement components.
Maintenance
- Inspect the system regularly for leaks, vibration, unusual noise, and pressure changes.
- Replace prefilters when the pressure differential reaches approximately 10–15 psi or when required by water conditions.
- Maintain a system operating log.
- Monitor feed and product-water TDS or conductivity.
- Track permeate flow, concentrate flow, pressure, recovery, temperature, and feed-water chemistry.
- Investigate changes in normalized production or rejection before membrane damage occurs.
- Flush and clean membranes only according to the applicable manual.
- Do not attempt to clean and reuse disposable filter cartridges.
- Maintenance frequency depends on feed-water quality, operating hours, recovery, pretreatment, and system conditions.
500 GPD
- 4-5/8” x 9-3/4” Pleated Cellulose Sediment Cartridge
- 4-5/8” x 9-3/4” SMART Filter Cartridge
- (2) 2.5” x 21” Freshwater Reverse Osmosis Membranes
750 GPD
- 4-5/8” x 9-3/4” Pleated Cellulose Sediment Cartridge
-
4-5/8” x 9-3/4” SMART Filter Cartridge
- 2.5” x 40” Freshwater Reverse Osmosis Membrane
1000 GPD
- 4-5/8” x 9-3/4” Pleated Cellulose Sediment Cartridge
-
4-5/8” x 9-3/4” SMART Filter Cartridge
- (3) 2.5” x 21” Freshwater Reverse Osmosis Membranes
1500 GPD
- 4-5/8” x 20” Pleated Cellulose Sediment Cartridge
- 4-5/8” x 20” SMART Filter Cartridge
- (2) 2.5” x 40” Freshwater Reverse Osmosis Membranes
1800 GPD
- 4-5/8” x 20” Pleated Cellulose Sediment Cartridge
-
4-5/8” x 20” SMART Filter Cartridge
- 4” x 40” Freshwater Reverse Osmosis Membrane
2500 GPD
- 4-5/8” x 20” Pleated Cellulose Sediment Cartridge
-
4-5/8” x 20” SMART Filter Cartridge
- (2) 2.5” x 40” Freshwater Reverse Osmosis Membranes
4000 GPD
- 4-5/8” x 20” Pleated Cellulose Sediment Cartridge
-
4-5/8” x 20” SMART Filter Cartridge
- 4-5/8” x 20” Coconut Based 5-Micron Carbon Block Filter Cartridge
- (2) 4” x 40” Freshwater Reverse Osmosis Membranes
5000 GPD
- 4-5/8” x 20” Pleated Cellulose Sediment Cartridge
-
4-5/8” x 20” SMART Filter Cartridge
-
4-5/8” x 20” Coconut Based 5-Micron Carbon Block Filter Cartridge
- (3) 4” x 40” Freshwater Reverse Osmosis Membrane
7000 GPD
- 4-5/8” x 20” Pleated Cellulose Sediment Cartridge
- 4-5/8” x 20” GAC Filter Cartridge
-
4-5/8” x 20” Coconut Based 5-Micron Carbon Block Filter Cartridge
-
4-5/8” x 20” SMART Filter Cartridge
- (4) 4” x 40” Freshwater Reverse Osmosis Membrane
- 500-2500 GPD Reverse Osmosis Manual
- 4000-7000 GPD Reverse Osmosis Manual
- RO Storage Tank Manual
- 500 GPD Reverse Osmosis Schematic
- 1000 GPD Reverse Osmosis Schematic
- 1500 GPD Reverse Osmosis Schematic
- 2500 GPD Reverse Osmosis Schematic
- 4000 GPD Reverse Osmosis Schematic
- 5000 GPD Reverse Osmosis Schematic
- 7000 GPD Reverse Osmosis Schematic